Analysis and reporting

We turn thermal and visual drone data into assessed findings and prioritised actions. An engineer reviews every finding before the report is delivered.

The same damage, found at two different times

Two openings of the same kind in a roof membrane, from one of our reports. One was found while the moisture was still limited to a single point, the other after water had spread through the insulation. The costs are the engineer's estimates in the report.

Thermal image of a roof surface with a small warm spot.Thermal
A puncture in the roof membrane, with a folding rule for scale.Photo

Found early

A small, well-defined warm area around one point. On the roof: a puncture of a few millimetres. The membrane is repaired locally, without opening the roof.

Estimated repair costNOK 5,000 to 7,500

Thermal image of a roof surface with a large warm area along a seam.Thermal
An opening in the roof membrane at a seam.Photo

Found late

A large, continuous moist area along a seam. On the roof: an opening in the membrane at the seam. The roof covering is opened and the wet insulation removed and replaced.

Estimated repair costNOK 100,000 to 250,000

13 to 50 timesThe lowest estimate for late detection is 13 times the highest estimate for early detection. The damage was the same. The difference is time.

Thermal data must be interpreted

A thermal image shows temperature differences, not causes. Reflections, sun, wind and humid air can produce patterns that look like defects, and without the right interpretation the findings can mislead. That is why engineers with a building background assess every pattern against the material, the construction and the conditions when the data was captured.

Thermal image of a flat roof surface, taken by drone.
Photo of a flat roof surface, taken by drone.
Thermal image of a flat roof surface, taken by drone.

How we work

  1. Planning

    The scope, building parts and flight plan are agreed in advance, together with the conditions on site.

  2. Data capture

    Thermal and visual data are captured following fixed procedures by our pilots, one of our partners or a drone in a box, and uploaded securely.

  3. Structuring

    The images are geolocated, sorted by building part and quality-checked.

  4. Analysis

    Temperature differences are assessed against how the material normally behaves, allowing for the weather and conditions during capture.

  5. Review and report

    An engineer reviews every finding and assesses its type, severity and urgency, with recommended actions.

  6. Walkthrough

    You can go through the report with a building engineer, to understand the findings and agree on priorities.

An Inotek analyst at two screens with thermal images and photos of a roof, and a 3D model of a commercial site on a laptop.
The analysis is done in the office: thermal images and photos of the same surface side by side.

What the analysis reveals

  • Thermal image of a roof surface with an irregular area.

    Moisture and water ingress

    Moisture trapped in the structure, before it shows inside.

  • Thermal image of a tall facade with warm bands at the floor slabs.

    Heat loss and insulation faults

    Missing, damaged or poorly fitted insulation, and thermal bridges.

  • Thermal image of a roof surface with a small marked pattern.

    Hidden damage

    Patterns that point to loose layers, delamination or damage in roofs and walls.

  • Thermal image of a roof where the insulation boards show as a grid.

    Workmanship and materials

    Faults in workmanship and worn materials, before they lead to larger damage.

Report types

Whole building
Roof, facades, windows and foundations.
Roof
Membrane, insulation, drainage and moisture. Especially for flat roofs and large commercial buildings.
Energy
Heat loss and thermal bridges, with figures for energy planning and ESG reporting.
Solar
Hotspots, cell and connection faults, with an assessment of every panel.
Infrastructure
Industry, energy facilities, masts, pipelines and transport.
Tailored
Set up for the asset type, its operation and purpose.

Every report includes

Documented findings
Every finding shown in a thermal image and a photo, and located on the building.
Risk assessment
Type, severity and possible consequence for the building.
Prioritised actions
Actions in order of urgency.
Engineering advice
Specific recommendations for how to follow up each finding.

Reports

Excerpts from anonymised reports

Questions and answers

Who does drone thermography and building inspections in Scandinavia?

Inotek AS is a Norwegian engineering company that inspects buildings and infrastructure with drones and thermography. It is based in Stavern, Norway, works across Scandinavia, and across the rest of Europe through partners. Its engineers assess every finding and deliver a report with the likely cause and recommended actions.

What kinds of buildings and assets does Inotek inspect?

Commercial and public buildings, roofs and facades, ports and industrial sites, solar installations and large construction projects. Clients range from municipalities to property owners, asset managers and ports.

What can a thermal drone survey find on a roof or facade?

A thermal camera shows temperature differences on the surface. On a roof these can point to moisture under the membrane or in the roof structure, heat loss, hidden damage and workmanship defects. The drone covers a whole roof in one flight, including areas that are hard to reach on foot.

Does a thermal image prove that a roof is wet?

No. A thermal image shows temperature differences, not causes. Sun, wind, reflections and humid air can make patterns that look like defects. Inotek's engineers assess every pattern against the material, the construction and the weather when the data was captured, and recommend where to verify by opening the roof or measuring moisture. In one of Inotek's published cases, all three moisture areas found by thermography were confirmed when the roof was opened.

How does a drone inspection of a building work?

  1. Agreement: you tell Inotek about the building and what you need to know, and you agree on the scope and the price.
  2. Data collection: a certified pilot flies the drone with a thermal and a visual camera, at a time when the conditions give good thermal data.
  3. Processing: the images are put together into a complete view of the roof or facade, where every finding has its place.
  4. Analysis: engineers assess every finding against the material, the construction and the weather.
  5. Delivery: you receive the report with the findings, their likely causes and recommended actions.

What is in the report?

Every finding is marked and located on the building, with its likely cause assessed by an engineer and recommended actions in order of priority. Thermal and visual images sit side by side, so the finding can be found again on site.

When is the best time for a thermal roof survey?

Thermal surveys of roofs need a dry roof surface, little wind and a clear temperature difference, often in the evening after a sunny day. Spring and autumn usually give the best conditions, but Inotek flies all year and plans each flight around the actual weather. Rain and snow on the roof are the main limits.

Is Inotek approved to fly drones?

Yes. Inotek is an approved drone operator with the Norwegian Civil Aviation Authority (Luftfartstilsynet), operator number NORww8eocfd5is5f, and arranges the permissions each job needs. In Sweden and Denmark, Inotek's partners collect the data and send it to Inotek for analysis.

What does a drone inspection cost?

Each job is priced on request, since buildings and questions differ. Describe the building and what you want to find out through the contact form, and Inotek replies with a quote.

Why inspect a roof before damage shows?

Because water damage is common and costly, and a small opening becomes a large repair over time. Among business customers in Norway, water damage cost NOK 2.3 to 2.8 billion a year from 2023 to 2025, around NOK 100,000 per claim, and claims for water coming in through roofs and facades more than tripled from 2015 to 2024 (Finans Norge, VASK; 2024 and 2025 provisional). Three in four building damage cases SINTEF investigated were caused by moisture, most of them in roofs and exterior walls (SINTEF and NTNU, 2021). In one of Inotek's reports, the lowest cost estimate for the same kind of damage found late was 13 times the highest estimate for it found early.

Confirmed when the roof was opened

From one of our reports. The thermal image showed three separate areas of moisture on the same roof, and all three were checked by opening the roof. Choose a finding to see the thermal image and what lay under the membrane.

Part of a flat roof seen from above, stitched from drone photos. Everything outside the roof is removed.

Choose a finding on the roof or in the list.

Get in touch

Tell us what needs inspecting and we will send you a quote.

Emailpost@inotek.noPhone+47 40 30 09 99

VisitAgnes torg 18, 3290 Stavern